Means op 4. Expiration date of a fire extinguisher - what affects this parameter and how to find it out. Scientific Innovation Center for Construction and Fire Safety


The powder fire extinguisher OP-4, which belongs to the primary fire extinguishing means, can be called one of the most common fire extinguishers that are equipped with the following premises:

Private houses,
- dachas,
- shops and warehouses,
- production shops,

Shelf life of powder fire extinguisher OP-4

Over the years of operation, it has been established that the shelf life of the OP-4 powder fire extinguisher from the date of manufacture (indicated on the cylinder and in the accompanying documentation) is at least 10 years. This has been confirmed by both manufacturers and operators. These results can be achieved if the following requirements are met:

1. Regular refilling of the fire extinguisher (at least 1 time in 5 years, but it is recommended - not less than 1 time in 2 years),
2. Checking the pressure in the cylinder (at least 1 time in 3 months. In case of detecting a pressure drop of the mixture by at least 10% of the set values, take measures to eliminate the causes of the pressure drop and refill),
3. Avoid sudden temperature changes (it is forbidden to store OP-4 near heaters, radiators, heaters, boilers, etc.)

At the same time, the manufacturer of fire extinguishers gives a guarantee for a period of 1.5 years from the date of its issue and no more than 12 months from the date of its sale. Further, the issue of maintenance falls entirely on the shoulders of the operators and the shelf life of the OP-4 powder fire extinguisher will correspond to the conditions of its use and scheduled maintenance.

What class of fires can OP-4 fight?

If you follow the instructions and accompanying documentation for the OP-4 powder fire extinguisher, it is designed to effectively fight against initial stage with fires of the following hazard categories:

A,
- V,
- WITH,
- sun

As we have already noted, this model belongs to the class of primary means of protection against fire and should be used to eliminate the most benign small fires before the arrival of the fire brigade.

Test fire extinguisher OP-4 in conditions close to real

The masters who tested various fire extinguishers, compared their characteristics, indicators, managed to determine that it was powder fire extinguishers that were the most effective devices.

Powder fire extinguishers can be successfully operated in a wide temperature range. At the same time, its consumer properties remain stable. After all, the composition includes a special powder, which, when in contact with fire, becomes foam. The foam barrier prevents the penetration of oxygen, so the fire goes out smoothly.

Purpose of powder fire extinguisher OP-4

Powder fire extinguisher OP-4 can be filled with various types of powders. Based on which modification is chosen, this fire extinguisher can be used to extinguish organic and solid objects, combustible raw materials, gaseous mixtures, as well as devices that are energized.

The main purpose of powder fire extinguishers OP-4 is the rapid extinguishing of various types of metals, structures, including this raw material. After all, some types of metals can burn without a constant supply of oxygen.


Powder fire extinguishers OP-4 have a unique design, including:

1. an integral case, in which a special powder is placed to eliminate the source of ignition;

3.special powder spray gun;

4.Additional components to adjust the flow, optimize the distance.

The mixture that is part of the fire extinguisher is in a compressed state, under a certain pressure. This is what allows you to supply the mixture to the required distance, to extinguish without worrying about your own health.

Free legal advice:


Application of powder fire extinguisher OP-4

  • various technical means, transport;
  • fire shields, which are equipped with industrial complexes, enterprises, factories, office blocks, residential premises and houses;
  • various divisions.

Such an extensive industry of using a powder fire extinguisher is due to the benefits that the consumer receives:

  • The total weight, dimensions of the powder fire extinguisher are small, so there are no difficulties with installation, dismantling, operation.
  • The weight of the charge is large enough, so it can be operated for a long time, to eliminate a larger source of ignition.
  • There will be no problems with operation, storage, if you first study the instructions, technical passport.

In order to activate the fire extinguisher, it is necessary to remove the seal immediately before the source of ignition, remove the pin, and also direct the nozzle directly onto the fire. There are no delays, so a quick response will help you prevent the fire from spreading. A fire extinguisher that has already been used can be recharged.

Technical characteristics of the powder fire extinguisher OP-4

1. The total weight of the fire extinguishing mixture, which is part of the OP-4 fire extinguisher, is about 4 kg.

2. A fully equipped fire extinguisher weighs about 6.5 kg.

Free legal advice:


3. The working jet can be blown up to a distance of about 3 meters.

4. The period of active action of the fire extinguisher is 10 seconds.

5.Storage time can be up to 10 years. But it is very important at the same time to strictly observe the rules of storage, take into account the features of operation.

The price of a powder fire extinguisher OP-4 in St. Petersburg

Now the cost of powder fire extinguishers OP-4 is diverse in St. Petersburg. Quite strongly it depends on such aspects as labeling, specifications, equipment. Regular customers, wholesale customers can count on certain discounts, the amount of which can be obtained directly from consultants and managers.

But in order for your expenses to be justified, you definitely need to carefully choose a modification. If you find it difficult to navigate on your own, involve the staff.

Certificate for fire extinguisher OP-4

Each OP-4 powder fire extinguisher must pass the certification and testing process. The results are recorded in the relevant documents.

Free legal advice:


In the process of manufacturing powder fire extinguishers, manufacturers are guided by the regulations defined by GOSTs. For example, GOSTs 2.601, R 51057, R are used in the preparation of markings, labels.

Testing is carried out in accordance with the normative act NPB-199, which spells out the basics and features.

In addition to the documents evidencing certification, the kit also includes technical passports and warranty cards.

Passport for fire extinguisher OP-4

The passport included in the set is prepared in accordance with the current standards and norms. The document contains information on the main technical indicators, features of storage and operation. All the information provided is true, there are no ambiguous interpretations. Therefore, there will be no difficulties either during the study or during operation.

Additional data must be entered into the passport if not only a fire extinguisher is purchased, but also additional accessories for it.

Free legal advice:


Expiration date of powder fire extinguisher OP-4

The shelf life of a powder fire extinguisher can be up to ten years. But in order for it to remain operational, function without problems, it is imperative to follow the prescribed storage rules.

Expiration date of the fire extinguisher OP-4

The powder fire extinguisher OP-4, which belongs to the primary fire extinguishing means, can be called one of the most common fire extinguishers that are equipped with the following premises:

Shops and warehouses,

Shelf life of powder fire extinguisher OP-4

Over the years of operation, it has been established that the shelf life of the OP-4 powder fire extinguisher from the date of manufacture (indicated on the cylinder and in the accompanying documentation) is at least 10 years. This has been confirmed by both manufacturers and operators. These results can be achieved if the following requirements are met:

Free legal advice:


2. Checking the pressure in the cylinder (at least 1 time in 3 months. In case of detecting a pressure drop of the mixture by at least 10% of the set values, take measures to eliminate the causes of the pressure drop and refill),

3. Avoid sudden temperature changes (it is forbidden to store OP-4 near heaters, radiators, heaters, boilers, etc.)

What class of fires can OP-4 fight?

If you follow the instructions and accompanying documentation for the OP-4 powder fire extinguisher, it is designed to effectively fight fires of the following hazard categories at the initial stage:

Test fire extinguisher OP-4 in conditions close to real

Free legal advice:


Scientific Innovation Center for Construction and Fire Safety

Expiry date of dry powder fire extinguisher

A powder fire extinguisher allows you to fight fires of class A, B, C, BC. Depending on the model and volume, it can be filled with various types of powder and pumped with various gases (nitrogen, air or carbon dioxide). The extinguishing process occurs due to the release of powder under high pressure.

The unit can be operated in a wide temperature range (minimum temperature -50, and maximum, respectively, +50 degrees Celsius). They are easy to use and convenient.

Speaking about the shelf life of a powder fire extinguisher op 4, it must be remembered that it must be regularly recharged (once every five years), and the gas pressure in the device must be checked - once every three months, at least. Regularly fulfilling all requirements for storage and operation, a powder fire extinguisher will last 10 years. The release date and all the characteristics of the device are indicated in its passport.

The manufacturer can guarantee accurate and uninterrupted operation of the device within 12 months from the date of sale of the fire extinguisher, but not more than one and a half years from the date of its release. The devices must not be installed near heating devices; direct sunlight and precipitation should not fall on it. The maximum allowable storage temperature of the device is +50 degrees.

If you violate the storage conditions, as a result, you will not be provided with warranty service.

Free legal advice:


The maximum duration of a powder fire extinguisher is seconds. Powder supply is intermittent. Moreover, it is recommended to keep a fire extinguisher no further than 3-4 meters from the source of direct ignition. This device is not intended for extinguishing substances that can burn without access to air. Its power and the duration of powder supply directly depend on the volume.

Powder fire extinguishers are widely used in everyday life, at enterprises and in cars. Fire extinguishers with a volume of 1 to 8 liters are considered portable, while those with a volume of 50 to 100 liters are mobile fire extinguishers. It is possible to recharge the cylinder at special stations, or by contacting a certified company providing such services.

Powder fire extinguisher OP-4

Powder fire extinguishers are the most versatile devices designed to extinguish almost all classes of fires and are used over a wide temperature range. A limitation for their use are fires initiated by the ignition of materials that burn without access to oxygen, for example, alkali or alkaline earth metals.

One of the most popular models of powder fire extinguishers is OP-4 (z) - ABCE. If we decipher this abbreviation, we get: a powder fire extinguisher with a nominal mass of fire extinguishing powder of 4 kg, pumping, designed to extinguish fires of classes A, B, C and E.

Free legal advice:


Where is the powder fire extinguisher OP-4 used?

Thanks to technical parameters and the versatility of the fire extinguishing powder, OP-4 is indispensable for extinguishing all types of fires, except for the burning of metals (class D):

  • class A - combustion of solid objects (paper, wood, plastic, etc.);
  • class B - combustion of liquids, both soluble and insoluble in water (gasoline, alcohol, glycerin, etc.);
  • class C - combustion of gases (propane, hydrogen, household gas, etc.);
  • class E - burning equipment and installations under high current.

The use of OP-4 at such facilities as:

  • public buildings;
  • warehouses;
  • industrial enterprises;
  • domestic buildings and premises;
  • delivery trucks;
  • minibuses,

efficient and cost-effective, which is proven in practice.

Specifications OP-4

Operation of the fire extinguisher OP-4 is possible in a wide temperature range - from minus 40°С to plus 50°С.

It is required to recharge the devices once every 5 years, the service life is 10 years.

Free legal advice:


These powder fire extinguishers are easy to use, easy to maintain, effective and safe for humans in fire fighting.

The technical parameters of OP-4 (h) are as follows:

  1. Capacity - 5 l.
  2. The mass of the charge of OTV is 4.0 ± 0.2 kg / l.
  3. Working pressure - 1.4±0.2 MPa.
  4. The duration of the powder supply in case of fire is 10 seconds.
  5. Jet length - 3 m.
  6. The mass of the cylinder is 6 kg. Dimensions - 13 cm diameter, 42 cm height.
  7. Fire extinguishing capacity - 2A (fire class A), 55V (class B).

The principle of OTV release is displacement under the action of excess pressure, which creates a working gas (carbon dioxide).

How to store powder fire extinguisher OP-4

To store OP-4 indoors, the devices are installed on the floor on special stands or mounted on the wall using brackets. As a rule, only a hose-bell and a passport for the product are included with the fire extinguisher, so brackets, stands and other necessary related products are purchased separately.

The location of the OP is chosen based on the points of GOST No. 12.4.009. The care of the OP consists in periodic checking of the appearance of the device, the strength of the fasteners, the integrity of the seal, and the removal of dust and contaminants from the surface.

Free legal advice:


A more detailed diagnosis of the serviceability of the fire extinguisher is carried out during the quarterly maintenance of the device. Once a year, the maintenance company conducts an opening of the OP and evaluates the parameters of the fire extinguisher. Recharging OP-4 is necessary every 5 years of operation or without fail after activating the device.

How to activate the powder fire extinguisher OP-4 (h)

In order to activate the fire extinguisher OP-4 of the pumping type in case of fire, it is necessary to perform the following actions:

  • direct the nozzle, from which the fire extinguishing agent will come out, to the source of ignition;
  • break the seal;
  • pull out the pin of the fire extinguisher, which is a metal rod bent at the end into a ring;
  • push the lever.

After activating the fire extinguisher, start extinguishing the fire.

Expiration dates of fire extinguishers are an important safety issue

The actual service life of a fire extinguisher is affected by several related factors, but there is also a service life approved by the standard, it depends on the type of fire extinguisher chosen. Based on these indicators, the maximum duration of storage of fire extinguishers at work, in public places, in cars is determined.

Free legal advice:


What are fire extinguishers

The classification defines the following types of fire extinguishers:

  • Powder. They are marked OP. The index indicates the mass of the charge (OP 5 - 5 kg, OP 4 - 4 kg). Powder extinguisher - universal device suitable for any type of fire - in electrical installations up to 1 kW, in oil storage facilities, in case of ignition of cars, in warehouses. The main extinguishing agent in a fire extinguisher is powder. According to the type of ejection, the jets are divided into gas generating (G), injection (Z), compressed air cylinder (B).
  • Carbon dioxide. They are labeled OU. The index also indicates the mass of the charge in the cylinder (OS 5 - 5 kg). A carbon dioxide fire extinguisher is used in electrical installations up to 1 kW in urban electric transport, on railway electric locomotives. The active substance is carbon dioxide under pressure, which varies depending on temperature. environment.
  • Air foam. ORP are marked. They have two types of active ingredients - chemical, foam consists of water and alkali, air-mechanical - from a foaming agent and water. Cannot be used in electrical installations. Use only for small fires of solids and flammable liquids.
  • self-acting modules. OSB marked. The active substance is a powder. Designed for fires of any class, they are also used in electrical installations up to 5 kW. A self-acting fire extinguisher is installed permanently in rooms with increased fire hazard, it is activated automatically, under the influence of smoke and flame. The OSB fire extinguisher has access to the most secluded corners of the room, inaccessible to people. Recommended for small areas.
  • Water. They are labeled OTV. The active ingredient is water. They are used for class A fires, and if there are additives in the water, then class B.

Powder and carbon dioxide differ in the volume of cylinders. They are portable - 1-10 liters and mobile - 20-100 liters. Mobile devices are often paired cylinders mounted on a special mobile cart.

What do the regulations say

  1. The shelf life of a powder fire extinguisher is 10 years for a cylinder and 5 years for a charge. At the same time, cylinders installed at the factory, in public places, require an annual scheduled check, which is indicated by a special note in their passport. Specialists of the fire supervision service check the condition of the active substance by opening individual cylinders from the whole batch. According to its results, an assessment of the state is given and, if necessary, fire extinguishers are sent for recharging.
  2. The shelf life of carbon dioxide type fire extinguishers is 10–15 years, depending on storage conditions. They also require an annual charge quality check. Specialists perform it by weighing the cylinder, determining the gas leakage and the condition of the shut-off valves. In production, a quarterly inspection is also carried out, which determines the installation site, appearance fire extinguishers. Every five years, the charge of a carbon dioxide fire extinguisher is renewed by completely discharging and cleaning from the remnants of the fire extinguishing agent. After that, a complete inspection of the integrity of the cylinder and a check of the tightness of the body are carried out.
  3. Storage of water and foam type fire extinguishers - no more than 1 year, after which they must be replaced. This type of device cannot be recharged.

Most types are also better to replace right away than to recharge. The cost of charging is most often equal to the cost of a new fire extinguisher.

Car fire extinguisher - what is the expiration date?

The rules for operating a car require a fire extinguisher in its cabin or at least in the trunk.

The ideal option is powder compact models - OP 2 for 2 kg of active substance, which does not contradict the requirements of the Rules. For greater security, it is better to give preference to a metal case over a plastic one.

Free legal advice:


When buying, you need to pay attention to the seal, it must be intact, as well as the certificate and expiration date (5 years per charge). The advantages of powder models are a medium-strength jet, compactness, and low price. The disadvantage is that when used, the powder clogs the territory and surface.

If you choose a carbon dioxide fire extinguisher, then its volume should not be less than the powder one, and these are models OU 2 and OU 3, by 2 and 3 kg of charge, respectively. The advantage of gas-type models is a good pressure of the working jet and complete evaporation of the active substance. The disadvantage is the toxicity of the substance, which requires work with gloves or with a special gasket and a low range of the working jet - 50–70 degrees.

The expiration date of a car fire extinguisher corresponds to its type:

  • Powder - 10 years for a cylinder, 2 years for a charge;
  • Carbon dioxide - 15–20 years per cylinder, 5 years per charge.

How to store

According to the Code of Rules, a fire extinguisher is required to be carried in the cabin, mounted on a bracket with a lock and a lock. The best place for these purposes - the passenger door, from there the cylinder can be easily removed and used in case of fire.

If the car is stored in an unheated garage or on the street, then it is better to use a powder type fire extinguisher. His temperature regime storage is from -40 to +50 ˚С.

Free legal advice:


But in the summer, it is better to avoid direct sunlight on the cylinder, for which you should protect the car with a special shading, reflective curtain. In carbon dioxide models, as the ambient temperature rises, so does operating pressure inside the cylinder, which must be taken into account.

Can I store a fire extinguisher in the trunk

If there was no place for a fire extinguisher in the cabin, then it is better to fix it in the trunk than not to have it at all. In this case, recharging will need to be done more often, due to the direct influence of the environment on the cylinder, at least once a year.

Any deviation in the operating conditions of the car and storage of the fire extinguisher affects its shelf life. Of course, no one will determine the performance by eye. If a fire extinguisher in a car is required only to pass a technical inspection and throw dust in the eyes of traffic police, then it is only important to observe right choice models and warranty periods on the fire extinguisher passport. For those who care about their own safety, it is better to do device replacement and routine inspections more often.

What to do with an expired fire extinguisher

This question is asked by most motorists, having learned that the service life has come to an end.

Due to the extreme operating conditions of a car fire extinguisher, it rarely lends itself to recharging. Better buy new model, with high reliability guarantees. But the old one can be used as a training projectile.

Free legal advice:


It is no secret that few drivers have tried to use a fire extinguisher in practice. So there will be a chance to master this technique on your own, at the same time checking the veracity of the declared characteristics - the length and density of the jet, the operating time.

You can refill the fire extinguisher, using it as a stationary device in the garage, in the house, in the country. Ideally, it's best to take your end-of-life device to a recycling center if one is available in your area of ​​residence.

How to find out the characteristics of a fire extinguisher yourself

All important parameters of the fire extinguisher are indicated in its passport, fixed directly on the cylinder. Mandatory of them are:

  • Factory number stamped directly on the passport;
  • manufacturer;
  • date of manufacture;
  • Working and test pressure;
  • The volume and weight of the balloon;
  • Factory OTK stamp.

When charging is performed, its date is affixed to the passport, and a control seal is installed on the cylinder.

Before buying a new fire extinguisher, it is better to immediately look at the device passport in order to determine for yourself how long it is guaranteed to serve you in the future. This knowledge will help to correctly determine the service life, recharge time, insuring against the questions of regulatory authorities - the fire safety department, traffic police services, and reduce the likelihood of fines.

Free legal advice:


The service life of each fire cylinder is determined by the developers and indicated in the technical documentation and passport. Each serviceable container has a seal, a blocking device and a marking.

Shelf life of fire protection equipment

  • powder - 10 years;
  • carbon dioxide -years;
  • air-foam (ORP) - 10 years.

Vehicle fire protection equipment has the following expiration dates:

  • freight and passenger transport - OU-2, OP-2 weighing at least 2 kg;
  • minibuses - OP-2, buses - OP-2, OP-5;
  • tank trucks - OP-5.

All fire extinguishers are classified according to the following criteria:

  • according to the method of action (automatic and manual);
  • the principle of the device;
  • according to the volume of the cylinder (from 1.6 to 400 kg);
  • by appointment;
  • on the design of launchers.

Characteristics of powder fire extinguishers:

  • used to extinguish fires of different classes;
  • are used when cutting off the flame in electrical equipment connected to a high-voltage line up to 1000 V;
  • adaptability to a wide temperature range (from -50° to +50°);
  • response time from 6 to 15 seconds;
  • the length of the ejection of the substance is from 2 to 6 m.

The disadvantage is the substance itself - the powder. After use, it clogs the room and objects.

Free legal advice:


Characteristics of carbon dioxide fire extinguishers:

  • are used for extinguishing liquid and gaseous substances, in case of fire in transport;
  • to cut off the flame in electrical equipment with a voltage not exceeding 1000 V;
  • wide temperature range (from -40° to +50°);
  • response time from 6 to 30 seconds;
  • the length of the substance ejection is 2-4 m.

Characteristics of air-foam fire extinguishers:

  • used to extinguish solid and liquid combustible substances;
  • have a long spray time (20-60 seconds);
  • temperature range is from +5° to +50°;
  • the length of the substance ejection is from 3 to 4 m.
  • limitation when extinguishing electrical equipment;
  • freezing at low temperatures;
  • unsuitability for extinguishing the flame of substances that react violently to water.

Check frequency

There are two types of inspections of fire extinguishers: quarterly and annual.

Inspection of the availability and serviceability of carbon dioxide type fire extinguishing equipment is carried out once a year. By weighing the cylinder and calculating the flame-extinguishing mass, the suitability is checked.

Powder cylinders are controlled at least once every 5 years by selective withdrawal and opening. The district inspector conducts scheduled inspections, which include inspection of the body of fire extinguishers. In addition to monitoring the expiration date, the fireman checks the integrity of the seals, the condition of the metal coating, the functioning of the shut-off device and the lock.

Free legal advice:


If damage is detected, the cylinder is sent for MOT (maintenance).

During the quarterly inspection, the presence, location and appearance of fire fighting equipment are mainly controlled.

Organizations specializing in the maintenance of fire extinguishing equipment perform the following types of work:

  • inspect the hull and trigger devices;
  • check with instruments;
  • perform performance tests;
  • reload;
  • repair worn parts.

Fire extinguishers for vehicles, regardless of type, are subject to annual inspection:

  • powder are diagnosed using indicators;
  • carbon dioxide - according to the results of weighing and calculating the mass of the extinguishing agent.

What to do when the expiration date has expired

All fire extinguishing cylinders must be recharged in a timely manner:

  • in case of using the funds;
  • if the leakage parameters of the composition exceed the permissible level;
  • during scheduled reloading.

Service life before recharging fire extinguishers:

  • carbon dioxide - 1 time in 5 years;
  • powder - 1 time in 5 years;
  • air-foam - 1 time per year;
  • water - 1 time per year.

Vehicle fire extinguishers installed outside the cab must be recharged once a year due to the direct influence of the environment on the body. Other transport fire extinguishers are subject to maintenance at least once every 2 years.

In reality, models with a foam or aerosol system do not recharge for various reasons:

  • design features and principles of operation of some models;
  • the cost of recharging will cost about the same as a new fire extinguisher.

End-of-life cylinders remain as training material or are scrapped. Water-based and foam-type fillers can be discharged into the production waste outlet by diluting with plenty of water.

Other types of extinguishing agents must be professionally removed from the hull. It is not allowed to drain them into drainage systems, since the composition has chemical elements that contribute to environmental pollution.

Therefore, in almost all cities there are points for receiving used fire extinguishing devices, where decommissioned cylinders should be handed over. There they are disassembled and sent for recycling.

Regulatory requirements SP 9.13130.2009 - the document contains sections:

  • Set of rules;
  • Fire fighting equipment;
  • fire extinguishers;
  • Operating requirements.
  • operational terms of fire extinguishing means;
  • types of cylinders and their purpose;
  • procedure for inspections and maintenance;
  • packaging and marking;
  • storage conditions and rules of use;
  • types of fire-fighting equipment used for vehicles.

Operating instructions

Powder extinguishing media

  1. Not allowed near cylinders heating elements.
  2. The temperature regime of storage must correspond to the temperature range of the fire extinguisher (-40°+50°).
  3. Recharging should be carried out on time and only in organizations specializing in the maintenance of fire fighting equipment. The maintenance information must indicate the type of powder being used.
  4. Transportation is allowed by all modes of transport.
    • hull condition;
    • working gas pressure (indicator readings should be in the green field in the range of 8-12 kgf / cm2);
    • quenching state.

The hull is subject to re-examination every 5 years.

Carbon dioxide extinguishing media

  1. The basic requirements for operation are indicated on the marking of the fire extinguisher body.
  2. Fire extinguishing devices should be located in prominent places or on a specially equipped fire shield.
  3. It is allowed to use a fire extinguisher at a distance of 1 meter to suppress the spread of fire in electrical appliances with a voltage of not more than 1000 V.
  4. Reloading should be carried out on time only in organizations specializing in the maintenance of fire fighting equipment. Returned cylinders must have a check and a seal.
  5. When using a fire extinguisher, you must follow the safety rules. Low temperature (-50°-70°) can injure parts of the body.
  6. After extinguishing the fire, it is necessary to ventilate the room from combustion products and carbon dioxide vapors.
  7. According to regulatory requirements, it is necessary to periodically monitor the working condition of fire extinguishing equipment. Allowable charge leakage should not exceed 50 g.
  8. Re-examination of the hull is carried out once every 10 years.
  9. There are no restrictions on the type of transportation of fire extinguishing equipment.

Air-foam type fire extinguishers

  1. The basic requirements for operation are indicated on the marking of the fire extinguisher body.
  2. Fire extinguishing devices should be located in prominent places or on a specially equipped fire shield.
  3. It is not allowed to place heating elements or sunlight near the cylinders.
  4. Recharging should be carried out on time only in organizations specializing in the maintenance of fire equipment. Returned cylinders must have a check and a seal.
  5. There are no restrictions on the type of transportation of fire extinguishing equipment. In frosty weather, it is allowed to transport cylinders without filler.
  6. Each cylinder is subject to periodic inspection:
    • hull condition;
    • working gas pressure (indicator readings should be in the green field in the range of 8-12 kgf / cm2).

Cancel reply

HQsignal - video surveillance systems. All rights reserved. Copying of material is possible with the placement of an active link to our source site.

OP-4 - a fire extinguisher (its characteristics must be studied), used in case of ignition of various combustible substances, problems with wiring (if the voltage is about 1000 V).

This model is the most popular. It features ease of use, convenient design, reliability. It is necessary not only to keep such fire equipment indoors, but also to know how to place it correctly, when to carry out maintenance.

Technical characteristics of the powder fire extinguisher OP-4. Complete set, passport

The OP-4 fire extinguisher device includes a trigger and a red cylinder containing powder inside. This is one of the most common models due to its cost, weight, dimensions, fire extinguishing abilities.

It is used to extinguish combustible materials, both solid and liquid, gaseous. Helps fight fires caused by wiring problems. But it is forbidden to use for extinguishing materials that can burn in an airless environment.

Before purchasing such fire equipment, it is imperative to study the overview of the characteristics of the OP-4 powder fire extinguisher:

  • the total mass of the fire extinguisher is about 6.3 kg, while the weight of the charge is 4 kg;
  • sizes - 42 and 15 cm;
  • type - download;
  • used filler - fire extinguishing powder;
  • operating pressure in the fire extinguisher - 1.4 MPa;
  • jet length - up to 3 m;
  • fire extinguishing powder exit time - not less than 10 seconds;
  • operating temperatures — from -30 to +500°С;
  • service life - up to 10 years.

Use and placement in the premises. Equipment standards

Scope: premises and vehicles.

Fundamental rules:

  1. Pull out the check ring. Then the seal is broken, which blocks the accidental activation of the device. Keep the bell in the direction of the place with fire. Pull the lever.
  2. When extinguishing a fire, do not stand against the wind.
  3. If a flat surface catches fire, then direct the jet first to the nearest place.
  4. If liquid substances are burning, extinguish from top to bottom.
  5. If the wall is on fire, then act from the bottom up.
  6. If there are several fire extinguishers, then use them at the same time at once, and not in turn.
  7. Make sure that the fire does not reappear in the treated areas.
  8. After the end of the use of OP-4, take it for refilling.

The OP-4 fire extinguisher must be placed so that it is not exposed to direct rays of the sun, heat, moisture do not act, there is no mechanical effect, no aggressive environment conditions.

According to the rules of safety and labor protection, it is necessary to place the structure in places where there will be quick access to them. It is best to leave near areas where ignition is most likely to occur, as well as near the exit from the room, in the corridors.

In warehouses and industrial premises, it is supposed to install special points with fire-fighting equipment. If there is a lot of equipment there, then there should be signs in easily visible places. They are supposed to be left at a height of about 2-2.5 m from the floor. The distance from the likely place of fire to the fire extinguisher should not be more than 20 m in public places. For category A, B and C - 30 m, for G - 40 m and 70 m - for D.

It is better to install the device on a special hanging stand or in lockers. In this case, all the inscriptions on it should be visible. trigger mechanism and locker doors need to be sealed. The model must be set up in such a way that it top part was no more than 1.5 m from the floor.

It is allowed to leave it on the floor, but in this case it is necessary to fix the device so that it does not fall. The distance to the door should be such that the device does not interfere with its opening and closing. Do not leave in a place where the temperature is not suitable. It is forbidden to use OP-4 for purposes not related to fire fighting.

Maintenance, periodic checks and recharging of the fire extinguisher

The used fire extinguisher OP-4 must be serviced, thereby maintaining it in constant readiness for use.

It is required to check the reliability of the functioning of all parts during the entire period of operation (the service life of the OP-4 fire extinguisher is 10 years). Maintenance involves inspections, tests, and, if necessary, repairs and reloading.

It is necessary to periodically check the device in order to monitor its condition. It is necessary to inspect the reliability of all nodes, the location, the availability of instructions, free access to a fire extinguisher.

Maintenance involves performing the following procedures at the following intervals:

  1. The study of all parameters and the ratio of the norm and actual indicators. Perform every year. The procedure is called recertification.
  2. Recharge. Perform every 5 years. The device is discharged and cleaned before being refilled. In addition, it is necessary to carry out the procedure if the device has been used or it has fallen. If the fire extinguisher is on the vehicle, then it must be recharged every 2 years. If the structure is not located in the cabin, but outside and is exposed to environmental factors, then the procedure should be carried out every 12 months.

At the time of checking the condition of the existing fire extinguisher, it is supposed to be replaced by another with the same model and performance.

Before putting the device into operation for the first time, it is required to carefully inspect it, check the availability of all parts, study the location, read the instructions (it should be simple).

During the review, you should check the following:

  • the presence of dents, scratches, chips in any place of the entire device;
  • clarity and simplicity of instructions;
  • the presence of a seal;
  • the correct operation of all mechanisms;
  • the presence of identifiers, inscriptions;
  • device weight;
  • the condition of the hose and sprayer;
  • stand reliability.

In the future, all points are noted in the product passport, then they are given a number in order (it is supposed to be written down directly on the device). The same data is entered into a special journal.

Once a quarter, you need to check the place where there is a fire extinguisher. If breakdowns or any deviations from the norm are detected, then it is required to identify the causes and eliminate the defects. All actions are recorded in the log book. Be sure to write the date of the check and any intervention.

  1. "Powder fire extinguisher OP-4 (h) (A, B, C, E)"- It is used for equipping cars, as well as trucks.
  2. "OP-4" is ideal for passing a vehicle inspection, for extinguishing solid, gaseous and liquid materials, as well as wiring with a voltage of not more than 1000V.
  3. Fire shields, offices, apartments, houses, shops, dachas, industrial premises, etc. are equipped with powder fire extinguishers "OP-4".
  4. "Powder fire extinguisher OP-4 (z) (A, B, C, E)" is charged with fire-fighting powder (Vixon), as well as carbon dioxide under a pressure of 16 atmospheres.

Instruction

  1. "Powder fire extinguisher OP-4 (h) (A, B, C, E)" is triggered by compressed gas (air, nitrogen, carbon dioxide), which is pumped into a cylinder under a pressure of 16 atmospheres.
  2. To bring the "OP-4" into action, it is necessary to pull out the check.
  3. Point the fire extinguisher socket at the fire from a distance of 3-4 meters from the windward side.
  4. With a hand, press the handle of the locking device (LPU), aeration and release of a fire extinguishing agent (OTV) occur.

Specifications

Application area

"Powder fire extinguisher OP-4 (z) (A, B, C, E)" is used to extinguish combustible substances of the class:
  1. A
    • combustion of solids accompanied by smoldering (eg coal, textiles);
    • burning of solids that are not accompanied by smoldering (for example, plastic).
  2. B
    • combustion of liquid substances insoluble in water (for example, gasoline, ether, petroleum products). Also, combustion of liquefiable solids (eg paraffin, stearin);
    • combustion of liquid substances soluble in water (for example, alcohol, glycerin).
  3. C
    • combustion of gaseous substances, domestic gas, propane and others.
  4. E
    • burning electrical installations, electrical wiring under voltage.

How to buy "Powder fire extinguisher OP-4 (z) (A, B, C, E)" and can the price be lower?

The price is 476.00 rub. The site is presented for retail. However, the company "PozhZaschita.RU" individually works with wholesale buyers, providing the best and competitive cost of commodity items. This is made possible through direct cooperation with manufacturers of products without intermediaries.

As regards the acquisition this product:

  • You can buy "Powder fire extinguisher OP-4 (z) (A, B, C, E)" right on this page, indicating all additional options;
  • take advantage of the most in a simple way, quick order form;
  • contact our manager directly, who will give you all the comprehensive information on the product, as well as provide professional advice on issues of interest.

How to receive the ordered goods or delivery methods

Our firm has representative offices in Krasnodar, Rostov-on-Don, St. Petersburg, Sevastopol and Simferopol. This means that you can buy or receive your purchase from a pickup point. For other regions of Russia, we offer delivery with various types carrying capacity and volume of the car body, urgent delivery or door-to-door delivery, cargo insurance and much more. We provide all the details on the cost and other questions on transportation when registering the shipment together with the carrier, since the number of ordered products may vary significantly.

Availability and consultation

A product such as "Powder fire extinguisher OP-4 (h) (A, B, C, E)" available almost always. When ordering in bulk, the required quantity will be delivered directly from the manufacturer's warehouses, providing the client with everything necessary. Do not forget that you may be offered best price on the market. If you are in doubt about the choice, be sure to look at related positions from section "Powder" on the site. Also, do not hesitate to get all the detailed information about "Powder fire extinguisher OP-4 (z) (A, B, C, E)" from our specialists.

Purpose of the product

Powder fire extinguisher, portable, pumping OP-4 is designed to extinguish fires of solid substances (fire class A), liquid substances (fire class B), gaseous substances (fire class C), as well as extinguishing electrical equipment under voltage up to 1000 V at industrial enterprises , warehouses, vehicles.

The OP-4 fire extinguisher is not designed to extinguish fires of substances that can burn without air. Fire extinguishers must be operated in moderate climate U, category 2 atmosphere type 11 according to GOST 15150-69 in the operating temperature range from -50° to +50°C.

The capacity of the OP-4 case is 4.9 liters, the mass of the charge is 4 kg. The fire extinguisher is designed to extinguish a fire object within 10 seconds with a jet length of 3 m.

Contents of delivery

The scope of delivery of the fire extinguisher includes:

  • fire extinguisher charged with a sealed ZPU - 1 pc.,
  • hose with nozzle - 1 pc.,
  • operation manual, combined with a passport for a fire extinguisher - 1 pc.

Device and principle of operation

The OP-4 fire extinguisher consists of a body filled with fire extinguishing powder. A locking and starting device with a pressure indicator is fixed on the neck. ZPU is equipped with a handle for carrying a fire extinguisher and a handle for controlling the supply of powder. The fire extinguisher is equipped with a siphon tube, a flexible hose and a spray gun to obtain a powder spray jet. The OP-4 fire extinguisher is equipped with a check to prevent self-activation. The principle of operation of a fire extinguisher is based on the use of the energy of the air pumped into the housing. To activate the fire extinguisher, it is necessary to pull out the pin, press the handle of the locking and starting device until it stops.

Operating and safety instructions

Not allowed:

  • storage of a fire extinguisher near heating devices, where the temperature may exceed +50°С;
  • fulfill repair work in the presence of pressure in the fire extinguisher body;
  • strike the body of the fire extinguisher;
  • operation of a fire extinguisher without checks and seals;
  • operation with faulty pressure indicator
  • exposure to aggressive environments.

How a fire extinguisher works

When extinguishing a fire, you must:

  • Bring the fire extinguisher to the place of fire, pull out the pin.
  • Make sure that the slot of the nozzle (sprayer) is perpendicular to the axis of the fire extinguisher body.
  • Direct the hose with the OP-4 sprayer to the fire.
  • Press the handle of the locking and starting device.
  • After the extinguishing is completed, it is necessary to immediately send the fire extinguisher for recharging, replacing it with the same type of backup fire extinguisher.

Maintenance

Recharge the OP-4 fire extinguisher at least once every 5 years.

Maintenance according to SP 9.13130.2009. Check the presence of pressure within the green scale of the indicator at least once a quarter. In the event of a pressure drop, pump at a service station.

Warranty

The manufacturer guarantees the compliance of the fire extinguisher with the technical specifications provided that the consumer observes the conditions of operation, transportation and storage.

The warranty period of the fire extinguisher is 12 months from the date of sale, but not more than 18 months from the date of manufacture.

The manufacturer is not responsible in the following cases:

  • Failure to comply with the rules of operation by the owner.
  • Careless storage or transportation of a fire extinguisher.
  • Lost your passport.
  • Absence of a manufacturer's seal

Technical certification

Technical examination is carried out at charging stations when recharging the fire extinguisher.

Charging certificate

Powder fire extinguisher, pumping OP-4 complies with GOST R 51057-2001 and TU 4854-001-21703266-2014 and is recognized as fit if the rules of transportation, storage and operation are observed. Disposal of powder fire extinguishers is carried out in accordance with NPB 166-97, the unusable cylinder body is handed over to organizations specializing in the acceptance and processing of ferrous metals. The date of manufacture is indicated on the label of the fire extinguisher.